Skip to content

Example run report

A run report shows what the calculator counted, what it did not count, and why. This example is the breast cancer screening measure (CMS125, 2026) run on a live eClinicalWorks FHIR R4 bulk export of 1,339 patients and about 1.8 million resources, evaluated on fqm-execution. It holds counts only: no patient identifiers.

Open the report in a new tab ↗
  • Reporting mode counts what the source coded, plus repairs, plus signed rules.
  • Quality-improvement mode also counts unsigned derivations and inferences, shown as a hatched segment so you can see which part of the rate rests on them.
Run Initial population Numerator
As published, no rules 278 0
Conformed, reporting mode 286 0
Conformed, quality-improvement mode 425 291
Production calculator, for reference 427 291

The published package scores zero. Mammograms in this export are coded only with the site’s radiology order text, and the inference that maps that text to LOINC is not yet signed.

Each row is one case the rules affected, with:

  • the population it affects;
  • the empty retrieve and the missing element;
  • the owner of the fix (Standards, Vendor or Site);
  • the rule that supplies the element, its class, and whether it is signed.

Filter by owner, rule class, signed status or population.

Rule Class Tier What it does
HCPCS code system relabel Repair Vendor HCPCS codes labelled as CPT are relabelled to HCPCS. The code is unchanged. 22,525 codings, 8 patients.
Clinical sex from administrative gender Inference Vendor Adds the US Core sex extension, inferred from Patient.gender. 139 patients.
Onset from recorded date Derivation Vendor Fills a missing Condition.onsetDateTime from recordedDate. 63 conditions, no population changed.
Radiology order text to LOINC Inference Site Maps seven radiology order names to LOINC mammography codes across 3,851 reports. 291 patients.

One proposed mapping was rejected. “Transfer of outside films” is an administrative act, not a mammogram, and would have added 120 false numerator events.

Reconciliation with the production calculator

Section titled “Reconciliation with the production calculator”

The production calculator has 427 eligible patients and the conformed run 425. Five patients are counted only by the production calculator and three only by the conformed run, all on plain office visits in the Office Visit value set. The numerators match at 291.